Overview of Typical Cases from Shenzhen’s Second Batch of Building-Integrated Photovoltaics (BIPV) and “Photovoltaic-Storage-Direct Flexible” Building Pilot Projects

Release Time:

2026-12-02


Overview of Typical Cases from Shenzhen’s Second Batch of Building-Integrated Photovoltaics (BIPV) and “Photovoltaic-Storage-Direct Flexible” Building Pilot Projects

To implement the requirements of documents including the State Council’s Action Plan for Peaking Carbon Emissions Before 2030, Guangdong Province’s Action Plan for Energy Conservation and Efficiency in Buildings (2023–2025), and Shenzhen’s 14th Five-Year Plan for High-Quality Development of the Modern Construction Industry, and to promote the large-scale application of renewable energy products and technologies in the building sector, a number of demonstration projects applying Building‑Integrated Photovoltaics (BIPV) and “Photovoltaic‑Storage‑Direct Current‑Flexible Load” technologies have been launched. To advance green, low-carbon, high-quality development in the construction field, entrusted by the Shenzhen Housing and Construction Bureau, the Municipal Construction Science and Technology Promotion Center organized and completed the solicitation, review, and certification of the second batch of BIPV and “Photovoltaic‑Storage‑Direct Current‑Flexible Load” pilot projects in Shenzhen. Following document review, expert evaluation, and public announcement, a total of five projects citywide were selected for the pilot program, with a combined installed photovoltaic capacity exceeding 3,073 kW. Specifically, four BIPV pilot projects were approved, accounting for over 2,965 kW of installed PV capacity; one “Photovoltaic‑Storage‑Direct Current‑Flexible Load” building pilot project was approved, with an installed PV capacity of approximately 108 kW. By summarizing and synthesizing Shenzhen’s technical approaches to implementing BIPV and “Photovoltaic‑Storage‑Direct Current‑Flexible Load” buildings, and by collating and sharing the technical measures and comprehensive benefits associated with these applications, this effort aims to provide replicable and scalable experience to support the implementation of pilot projects across the city.


 

List of Shenzhen’s Second Batch of Building-Integrated Photovoltaics (BIPV) and “Photovoltaic-Storage-Direct Current-Flexible Load” Building Pilot Projects


 

Comprehensive Development Research Institute


 

◆ Project Overview


 

The project is located at No. 38, Jinhu Road, Yinhuhu Community, Qing Shui He Subdistrict, Luohu District. The renovation comprises four components: thermal insulation and waterproofing repair of the metal roof, landscape enhancement, installation of a monocrystalline silicon photovoltaic power generation system, and installation of a copper indium gallium selenide (CIGS) high-efficiency thin-film photovoltaic power generation system. Specifically, 260 square meters of new steel roofing structure were added, 380 square meters of the existing metal roof were repaired, the installed capacity of the photovoltaic system is 174.05 kW, and corresponding landscape improvements were carried out.


 

◆ Building-Integrated Photovoltaics Technology


 

The primary application scenario for building-integrated photovoltaics (BIPV) in this project is on the roof. By utilizing 260 square meters of newly added steel structure, a total of 25.62 kW of N-type BC‑type monocrystalline silicon PV modules were installed using an aluminum alloy system profile integrated with structural waterproofing. Additionally, by repairing the existing metal roof and selecting TPO material with a service life of up to 35 years, a 42.9 kW flexible copper indium gallium selenium (CIGS) high‑efficiency thin‑film photovoltaic system was installed. This approach maximizes the effective use of roof area while expanding public activity space and enhancing the landscape. Together, these components form a BIPV system that operates in parallel with the existing grid under a distributed generation model of “self‑generation and self‑consumption, with surplus power fed back to the grid,” achieving synergistic benefits in thermal insulation, waterproofing, energy conservation, and carbon reduction.


 

◆ Comprehensive Benefit Analysis


 

The project utilizes idle rooftop space to install distributed photovoltaic systems, implementing an integrated building‑PV design. This approach increases public activity areas, addresses roof leakage and thermal insulation issues, enhances the aesthetic appeal of the building’s “sixth façade,” ensures reliable solar power generation, and reduces community carbon emissions. It also explores the feasibility of a third‑party investment and energy‑performance contracting model for integrated building‑PV installations. Calculations show a comprehensive cost of approximately RMB 5.2 per watt, with a total installed capacity of 170.05 kW, an average annual generation of 200,000 kWh, and a reduction of 202 tonnes of CO₂ emissions. Based on an average daytime electricity price of RMB 0.9 per kWh, the project yields annual savings of about RMB 180,000 and generates an additional RMB 100,000 from roof repair value. The investment payback period is six years, demonstrating strong economic and environmental benefits.


 


 

Second Office Building of the Pingshan District Government


 

◆ Project Overview


 

The project is located at No. 5068 Pingshan Avenue, Pingshan District, covering a site area of approximately 30,000 square meters. It features a photovoltaic installation spanning 7,000 square meters with an installed capacity of 1,383.47 kilowatts. By implementing five key measures—leveraging renewable energy, reducing the building’s inherent energy consumption, promoting efficient resource utilization, enhancing landscape and vertical greening, and establishing a carbon emissions management and monitoring system—the project serves as Shenzhen’s first pilot demonstration of a near-zero-carbon office building for Party and government agencies.


 

◆ Building-Integrated Photovoltaics Technology


 

The project has a rooftop installed capacity of 94 kW and a photovoltaic carport installed capacity of 1,289.47 kW, classifying it as a distributed photovoltaic power generation project. In total, it utilizes 6,465 square meters of roof area on the photovoltaic carports. The project employs 2,743 polycrystalline solar photovoltaic modules, with an estimated total electricity generation over 25 years of approximately 2,957.29 MWh. While achieving building-integrated photovoltaics, it also provides roof insulation and energy savings, exploring the share of renewable energy in the overall energy consumption of public institutions. The project includes an energy monitoring platform capable of tracking and analyzing energy consumption metrics such as photovoltaic power generation, photovoltaic electricity usage, excess photovoltaic power fed into the grid, and energy storage charge/discharge volumes.


 

◆ Comprehensive Benefit Analysis


 

Under an energy performance contracting model, the electricity generated by the photovoltaic system at Pingshan District Government’s Second Office Building is paid for at a discounted real-time tariff. Operating on a “self-consumption with surplus fed to the grid” basis, the system enables local consumption of solar power. With a total installed capacity of 1,383.47 kW—comprising 94 kW on rooftops and 1,289.47 kW in photovoltaic carports—the plant generates an average of 1.2 million kWh annually and reduces carbon dioxide emissions by approximately 800 tons per year.


 


 

Ruihe Industrial Park, Shenzhen-Shantou Special Cooperation Zone


 

◆ Project Overview


 

The project is located in the Ruihe Industrial Park on Xinyuan Road, Ebu Town, Shenzhen-Shantou Special Cooperation Zone. Covering a land area of 72,000 square meters with a total floor area of 112,600 square meters, the park includes office buildings, factory halls, dormitories, a canteen, and sports courts. It serves as a new‑type building materials production base integrating manufacturing, R&D, and sales. Adopting a “self‑generation for self‑use, with surplus power fed into the grid” model, the project not only meets the enterprise’s own electricity needs but also supplies green, clean power to the park, thereby contributing positively to energy conservation, emissions reduction, and ecological protection. At the same time, it sets a new benchmark for industrial development within the Ruihe Industrial Park and the Shenzhen‑Shantou Special Cooperation Zone.


 

◆ Building-Integrated Photovoltaics Technology


 

The project’s application scenarios are diverse, including building rooftops, curtain walls, sunrooms, photovoltaic carports, photovoltaic corridors, photovoltaic streetlights, and sound barriers. Specifically, the rooftops of dormitory buildings 1–3, factory buildings 1–2, the wood-products factory, and the distribution room utilize monocrystalline silicon photovoltaic modules, while the rooftop of factory building 3 employs cadmium telluride photovoltaic modules, which also provide shading and waterproofing functions. The south-facing curtain wall of dormitory building 1 uses cadmium telluride photovoltaic modules, integrating power generation, aesthetics, ventilation and daylighting, and external enclosure into a single system. By incorporating solar energy into the architectural façade design and achieving an organic, seamless integration, this approach has created a new type of architecture that unites structure, technology, and aesthetics. The entire exterior of the sunroom replaces conventional building materials with green photovoltaic building materials—patterned cadmium telluride thin-film photovoltaic glass—and incorporates decorative patterns into the glass, reflecting a design philosophy that blends smart energy, green ecology, and technological innovation. The photovoltaic corridor combines cadmium telluride photovoltaic glass with colored-glazed glass to shelter pedestrians from wind and rain while enhancing the campus environment. The photovoltaic pavement uses anti-slip glass to improve road performance, prevent water pooling, and integrates pressure-sensitive LED strips to deliver dynamic nighttime landscape lighting. Finally, the sound barrier is a novel eco-friendly facility that integrates solar power generation with noise reduction; through absorption, isolation, and power generation, it mitigates environmental noise pollution, improves urban air quality, and reduces carbon emissions.


 

◆ Comprehensive Benefit Analysis


 

The rooftop photovoltaic installation also functions as a “sunshade”; after installing PV panels on the roof, indoor temperatures drop by 4–6°C. A photovoltaic “breathing” ventilated curtain wall on the building façade further reduces the building’s energy consumption. Calculations show that with PV installed on both the roof and façades, the installed capacity is 1,288.16 kW, with an annual generation of 1.1 million kWh and a lifecycle CO₂ reduction of 16,000 tonnes. Under a “self-generation for self-consumption with surplus fed to the grid” model, the park’s on-site consumption rate is about 57%. The investment is expected to be recovered in around six years after implementation, and the project serves as a useful demonstration of the feasibility of applying photovoltaic systems across multiple scenarios.


 

Xiacun Primary School Demolition and Reconstruction Project


 

◆ Project Overview


 

The project is located on the southwest side of the intersection of Siyuan Road and Fuli Road in Gongming Subdistrict, covering a land area of 10,815.34 square meters with a total floor area of 29,999 square meters. The building’s primary functions include teaching and ancillary spaces, office facilities, dormitories, and an outdoor sports field.


 

◆ Building-Integrated Photovoltaics Technology


 

The project installs photovoltaic panels on the roof using a load-bearing, fixed, flat‑mount installation method, with the panel tilt aligned flush with the racking. Beneath the PV modules lies a rooftop garden. The system configuration comprises PV array inverters, an AC grid‑connection cabinet, and an AC distribution system, enabling on‑site consumption of self‑generated power with surplus electricity fed back to the grid. The rooftop racking supports PV arrays consisting of 220 JMPV‑X1/72‑550 monocrystalline silicon solar modules, achieving a photoelectric conversion efficiency of 21.1%. Integrated with the rooftop landscape pergola, the PV system generates clean energy without compromising the use of the green roof for planting or the ecological farm education demonstration site, while also providing shade.


 

◆ Comprehensive Benefit Analysis


 

The project integrates building-integrated photovoltaic (BIPV) systems with the building’s form, functional spaces, and environmental context. By fully leveraging renewable energy, it also provides rooftop shading and supports educational initiatives related to ecological farming. Calculations show that with an installed capacity of 121 kW, the rooftop distributed PV system will generate 125,000 kWh in its first year, reducing CO₂ emissions by 52.3 tons annually. Accounting for a 1% performance degradation in the first year and 15% over 25 years, the system is expected to produce 2.897 million kWh over its 25-year lifetime, averaging 116,000 kWh per year. Based on the school’s electricity tariff of RMB 0.6912 per kWh, annual savings amount to RMB 80,000, resulting in an investment payback period of approximately eight years.


 

Kindergarten for the Bihai Garden Slum Renovation Project (Hejunfu) in Baoceng District 43, Xin’an Subdistrict


 

◆ Project Overview


 

The project is located on the southwest side of the intersection of Chuangye 1st Road and the Guangzhou–Shenzhen Highway in Xin’an Subdistrict, Bao’an District. It covers a site area of approximately 2,700 square meters, with a total floor area of about 2,900 square meters, and will serve as a kindergarten. The project explores applications of a new “photovoltaic–storage–direct current–flexibility” power system, using photovoltaics as the primary energy source and leveraging energy storage to further enhance energy efficiency and the on-site integration of renewable energy, thereby establishing a pilot near-zero-carbon kindergarten.


 

◆ “Photovoltaic-Storage-Direct Flexibility” Building Technology


 

The project integrates with the building’s architectural form, utilizing favorable horizontal surfaces—such as non-accessible roofs, fall-protection nets, and shading canopies—to capture solar irradiance, and deploys monocrystalline silicon photovoltaic modules with high photoelectric conversion efficiency. Specifically, the shading canopy incorporates monocrystalline silicon PV modules fitted with 20% translucent tempered glass facades, satisfying requirements for structural safety, photovoltaic power generation, adequate daylighting, and aesthetic harmony. The system includes energy storage of a specified capacity; photovoltaic generation first powers DC lighting, with any surplus charging the storage unit, and additional excess fed back to the grid via an FCS flexible bidirectional converter. When PV output is insufficient, the storage supplements the supply; if storage falls below its threshold, the utility grid provides the balance. By augmenting conventional energy-storage converters with bidirectional voltage regulation, the stability of the PV–storage–DC–flexible system is enhanced. A low-voltage DC distribution network integrating PV, storage, DC loads, and flexible control enables local consumption of renewable energy, directly absorbing DC loads and greatly simplifying power conversion stages while avoiding the adverse impact of traditional grid-connection methods on grid power quality. Addressing the complexity of coordinating diverse power electronic devices in conventional microgrid architectures, this approach leverages the operational characteristics of flexible power electronics, combining maximum power point tracking (MPPT) algorithms with precise voltage- and current-limiting control. Through voltage-band control, optimized coordination among system components is achieved, resolving the issues of intricate control logic and reduced reliability inherent in traditional methods.


 

◆ Comprehensive Benefit Analysis


 

Calculations show that with a rooftop distributed photovoltaic system installed at 115 kW and an average annual generation of 126,500 kWh, at a tariff of RMB 0.6912 per kWh, annual electricity cost savings would amount to RMB 87,000. The project features well-planned building-integrated photovoltaic applications, meeting requirements for structural safety, green energy production, and aesthetic harmony. A DC power supply and distribution system has been implemented in public spaces; combined with DC lighting and energy storage systems, this enables high‑rate self‑consumption of PV generation and flexible regulation and storage, actively exploring key technological applications for the new “PV‑storage‑DC‑flexible” power system.


 


 

(Affiliation of the author: Shenzhen Construction Science and Technology Promotion Center)

 


Relevant attachments


Help the construction of green energy buildings and strive to become the leader in the BIPV industry.

Contact Us

Contact Us

Contact: Mr. Li

Tel: 13564139588

Email: yaocheng.li@jz.solargiga.com

Address: Building 1, Yintan Cultural and Creative Park, No. 88, Yapeng Road, Jianye District, Nanjing City, Jiangsu Province

COPYRIGHT © 2023 Nanjing Green Building Optoelectronics Co., Ltd. SEO

Business License